Cathodic Protection Network
Wednesday, 13 March 2013
Wednesday, 13 February 2013
20130213 Cathodic Protection Network Progress
Cathodic Protection Network International.
There are many followers of Cathodic Protection Network who are waiting for me to send proposals about the formation of Cathodic Protection Network International Ltd.
Others are standing by and waiting to jump on the band wagon as soon as we start making money.
The product of Cathodic Protection network technology that is controlling corrosion by electrical means.
Corrosion is causing damage to the environment, loss of life, loss of energy and water and loss of profits to multinational companies globally proving that the present service industry of corrosion control is not as efficient as it could be.
The following activities cannot work in competition but must be coordinated into a single organisation At present there are privately owned companies that train and certify specialists through a variety of activities.
Consultancy.
Training
Manufacture
Field survey and engineering.
Software development.
In order to deliver the control of corrosion to the end user the company Cathodic Protection Network International Limited must be an identifiable entity for legal, financial and operational purposes.
We therefore require interested parties in the fields of expertise to contact the company using the email address ralexander1938@googlemail.com
Each comment on this posting describes a field of expertise that the company requires.
Saturday, 9 February 2013
Many of the water pipeline leakages in the UK could be due to inteference from the cathodic protection systems of the oil and gas pipelines.
All cathodic protection systems alter the electrical equilibrium of remote earth
with respect to all conducive paths that might provide a return path to negative of
the source of energy. Electrical energy passing from metal into electrolyte dissolves
metal in proportion to the current. This causes pipelines to leak. Have any of the
learned bodies and institutions advised the water distributors about this matter and
what is their advice?
Monday, 28 January 2013
The half-cell is not a reference electrode.
I have been told by highly qualified scientists that is it not even a half-cell
...
http://www.rogeralexander1938.webspace.virginmedia.com/cpn/halfcell/halfcell.htm
...
The link shows pictures that prove that the copper/copper-sulphate electrode is merely a suitable ground contact.
Sunday, 27 January 2013
Cathodic Protection Network Master Class
How to control corrosion in pipeline systems.
It has been suggested that I hold a 3 day master class for Cathodic Protection Network technology and it will be a good opportunity to explain the significant changes that are presently happening to the whole of the cathodic protection industry.
It has been suggested that I hold a 3 day master class for Cathodic Protection Network technology and it will be a good opportunity to explain the significant changes that are presently happening to the whole of the cathodic protection industry.
This is a scientific and technical blog
Please keep opinions to the minimum and base postings on facts that are established by repeatedly demonstrable observations that you are prepared to support with documentation, pictures mathematical calculations etc.
Scientific papers and some codes of practice contain words and characters derived from Greek and Latin and are not in general use by the people who have to apply the advice they advocate.
Cathodic Protection Network is a facility to bridge the gap between the elite academics and the people who walk miles over pipelines gathering data and noting crucial information.
Scientific papers and some codes of practice contain words and characters derived from Greek and Latin and are not in general use by the people who have to apply the advice they advocate.
Cathodic Protection Network is a facility to bridge the gap between the elite academics and the people who walk miles over pipelines gathering data and noting crucial information.
International reference potential
When we make voltage measurements pertaining to two or more pipelines we have to relate these to a reference potential in a fixed position so that we can understand the direction of flow of electrical currents.
Corrosion committees are already required by law to mitigate interference corrosion between pipeline owners and their measurements must relate to a common potential to make any sense. There are no boundaries to pipeline networks and we therefore need a common reference potential in the same way that we need the conventions on international time.
Corrosion committees are already required by law to mitigate interference corrosion between pipeline owners and their measurements must relate to a common potential to make any sense. There are no boundaries to pipeline networks and we therefore need a common reference potential in the same way that we need the conventions on international time.
Subscribe to:
Posts (Atom)